Ideal storage conditions for your precious blood cells
KN Series Blood Bank Refrigerators are specifically designed to optimize the storage of blood and blood components. Drawers are designed to hold the maximum number of bags in the smallest footprint, while maintaining them in a convenient position for label reading and minimizing heat-up during opening.
KN Series Blood Bank Refrigerators are powered by N-Smart™ which has internal memory storing temperatures records up to ten years with on...
KN Series Blood Bank Refrigerators are specifically designed to optimize the storage of blood and blood components. Drawers are designed to hold the maximum number of bags in the smallest footprint, while maintaining them in a convenient position for label reading and minimizing heat-up during opening.
KN Series Blood Bank Refrigerators are powered by N-Smart™ which has internal memory storing temperatures records up to ten years with one hour intervals as digitally and graphically. By means of Wi-Fi connection and N-Mobile™ application, KN Series Blood Bank Refrigerators can be traced anywhere and notification can be received instantly. Sample safety is given top priority with audible, visual, open door and optional NuveWarn™ remote alarm system, plus an optional AlerText™ text message to multiple mobile phones. Sending e-mail up to five e-mail addresses in case of any failure is offered as standard. Alarms are independently powered by a permanently recharged battery.
|
KN 72 |
KN 120 |
KN 294 |
|
---|---|---|---|---|
Nominal Storage Capacity, Blood Bags* |
72 pcs. |
120 pcs. |
294 pcs. |
|
Gross Chamber Volume, Litres |
200 |
304 |
632 |
|
Net Chamber Volume, Litres |
165 |
269 |
568 |
|
Display |
4,3'' Colourful LCD Display |
|||
Control System |
N-Smart™ Control System |
|||
Temperature Range |
0°C / 10°C |
|||
Temperature Set And Display Sensitivity |
0.1°C |
|||
Temperature Sensor |
Pt 100 |
|||
Temperature Uniformity @+4ºC |
±1 °C |
|||
Temperature Alarm |
Set temperature ±2°C. Audible and Visual |
|||
Power Failure and Door Alarm |
Audible and Visual |
|||
Remote Alarm Contact |
For all Alarm Conditions |
|||
Alarm Back-Up |
Automatic Re-chargeable Battery for 12-hour |
|||
Door |
Insulated Steel Frame with Triple Glass Window and Key Lock |
|||
No. of Drawers |
3 |
5 |
6 |
|
Insulation |
High Density Injected Polyurethane |
|||
Internal Material |
Stainless Steel |
|||
External Material |
Epoxy-Polyester Powder Coated Stainless Steel |
|||
Power Rating |
330 W |
330 W |
800 W |
|
Power Supply |
230 V, 50/60 Hz |
|||
Chamber Dimensions (WxDxH) mm |
478x545x768 |
478x545x1168 |
738x635x1348 |
|
Net Internal Dimensions (WxDxH) mm |
478x545x633 |
478x545x1033 |
738x635x1213 |
|
External Dimensions (WxDxH) mm |
610x805x1255 |
610x805x1855 |
917x895x1985 |
|
Packing Dimensions (WxDxH) mm |
700x860x1430 |
700x860x2040 |
1030x1020x2140 |
|
Net/Packed Weight, kg |
120/136 |
180/205 |
275/305 |
|
* Nominal storage capacity may vary according to the loading method and preferences. |
FACTORY FITTED OPTIONS
KN XXX Y | Battery operated 7-day chart recorder |
OPTIONS
A 08 195 | NüveCloser™ Software CD with 3 m. RS 232 cable |
A 08 231 | NüveCloser™ Multi Software (Connection up to 15 devices) |
A 08 191 | AlerText™ GSM alarm module |
K 13 009 | NüveWarn™ remote alarm system with 10 m cable |
|
KN 72 |
KN 120 |
KN 294 |
|
---|---|---|---|---|
Nominal Storage Capacity, Blood Bags* |
72 pcs. |
120 pcs. |
294 pcs. |
|
Gross Chamber Volume, Litres |
200 |
304 |
632 |
|
Net Chamber Volume, Litres |
165 |
269 |
568 |
|
Display |
4,3'' Colourful LCD Display |
|||
Control System |
N-Smart™ Control System |
|||
Temperature Range |
0°C / 10°C |
|||
Temperature Set And Display Sensitivity |
0.1°C |
|||
Temperature Sensor |
Pt 100 |
|||
Temperature Uniformity @+4ºC |
±1 °C |
|||
Temperature Alarm |
Set temperature ±2°C. Audible and Visual |
|||
Power Failure and Door Alarm |
Audible and Visual |
|||
Remote Alarm Contact |
For all Alarm Conditions |
|||
Alarm Back-Up |
Automatic Re-chargeable Battery for 12-hour |
|||
Door |
Insulated Steel Frame with Triple Glass Window and Key Lock |
|||
No. of Drawers |
3 |
5 |
6 |
|
Insulation |
High Density Injected Polyurethane |
|||
Internal Material |
Stainless Steel |
|||
External Material |
Epoxy-Polyester Powder Coated Stainless Steel |
|||
Power Rating |
330 W |
330 W |
800 W |
|
Power Supply |
230 V, 50/60 Hz |
|||
Chamber Dimensions (WxDxH) mm |
478x545x768 |
478x545x1168 |
738x635x1348 |
|
Net Internal Dimensions (WxDxH) mm |
478x545x633 |
478x545x1033 |
738x635x1213 |
|
External Dimensions (WxDxH) mm |
610x805x1255 |
610x805x1855 |
917x895x1985 |
|
Packing Dimensions (WxDxH) mm |
700x860x1430 |
700x860x2040 |
1030x1020x2140 |
|
Net/Packed Weight, kg |
120/136 |
180/205 |
275/305 |
|
* Nominal storage capacity may vary according to the loading method and preferences. |
FACTORY FITTED OPTIONS
KN XXX Y | Battery operated 7-day chart recorder |
OPTIONS
A 08 195 | NüveCloser™ Software CD with 3 m. RS 232 cable |
A 08 231 | NüveCloser™ Multi Software (Connection up to 15 devices) |
A 08 191 | AlerText™ GSM alarm module |
K 13 009 | NüveWarn™ remote alarm system with 10 m cable |